Toshiba IK-DP20A User Manual Page 33

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 32
Camera Address = 1 x bit1 Status + 2 x bit2 Status + 4 x bits Status + 8 x bit4
Status + 16 X bits Status + 32 x bit6 Status + 64 x bit7
Status + 128 X bit8 Status
*bit Status: On=1 ,Off=0
ex) Camera Address 200 =1 x O(Off) + 2 x O(Off) + 4 x O(Off) + 8x1 (On) + 16
X O(Off) + 32 X O(Off) + 64 X 1(On) + 128 x 1(On)
= 8+64+128=200 — Off/Off/Off/On/Off/Off/On/On
(2) SW2(bit1-2) Protocol
Protocoi biti bit2
TOSHIBA-P Off Off
TOSHIBA-D On Off
Reservel Off
On
Reserve2
On On
(3) SW2 (bit3-4) Bit Rate
Protocol bit3 bit4
1200bps
Off
Off
2400bps On Off
4800bps Off
On
9600bps
On On
(Dome base switch:S301)
This is RS422 termination switch iocated near the BNC connector,
in daisy chain operation system, the farthest dome from the controlier is
turned ON.
For exampie, when the controlier is connected with three dome cameras
in the direct mode, the only furthest dome camera from a controller is
turned ON. The other dome camera is turned OFF. (It is OFF at the time
of shipment.)
ON and OFF are as in a figure.
-32-
Page view 32
1 2 ... 28 29 30 31 32 33 34 35 36

Comments to this Manuals

No comments