System Configuration Setup
Disk array (RAID) setting
151
Disk array (RAID) setting
If the server has RAID controllers, the disk array (RAID) must be set. Auto-
matic installation using Toshiba Server Setup Tool or custom installation
using Simplified Setup sets the optimum data for the disk array automati-
cally. To conduct custom installation using Detail Setup, the disk array must
be set. Refer to the MegaRAID Users Manual.
NOTE: Refer to the Installation Guide or Online Help for the installation
procedure that requires using Toshiba Server Setup Tool.
Installing the RAID Utility
Before using RAID controllers, be absolutely certain to install the RAID Utility
for the operating system. For example, install Power Console for Windows
NT or MegaRAID Manager for NetWare. Installation of inappropriate utility
will make it impossible for drives to be hot-swapped, or replaced, during the
operation of the drives if they suffer a fault.
NOTE: Before using Windows NT, be sure to install the NT Server Monitor.
All MegaRAID error messages can then be confirmed using the NT Event
Viewer.
Refer to the MegaRAID Software Users Manual for further details of instal-
lation.
Operations to be performed if a very heavy load is applied
The events that may occur if the system load increases significantly are listed
below.
The following message is displayed at the Application Log of the NT
Event Viewer:
Event ID:9
Source:mraid35x
(Explanation) Device SCSI Port did not reply within the timeout.
If Power Console is aborted during execution, the following message will
be displayed:
No MegaRAID Adapter crd found!
[OK]