7.4 1-pulse trigger
Exposure starts by the trigger signal input to the DIGITAL terminal, and outputs a 1-frame
image. The shutter speed (exposure period) is set with the MODE SELECT switch No. 6 -
No. 8 on the rear panel.
Input signal: Trigger
Output signal: Video data, pixel clock, FEN/VD, LEN/HD
Exposure period
Video data
(video period image)
HD
Trigger
VD
FEN
LEN
7.5 1-pulse trigger partial readout
This is the mode for partial scanning by the 1-pulse trigger operation.
Input signal: Trigger
Output signal: Video data, pixel clock, FEN/VD, LEN/HD
HD
Trigger
VD
FEN
LEN
Video data
(video period image)
Exposure period