10. PROGRAMMING PROCEDURES
10.16 BAR CODE FORMAT
10-26
10.16 BAR CODE FORMAT
Menu Page: 2
Item No.: 6
With the H-9100N scale, four kinds of bar code formats are available. These formats can be
changed freely.
When changing the above example format into the weigh format described in NOTE 1, use the
following procedure.
NOTES:
1. In this scale, the previously set bar code format is initialized to the following default by RAM clear.
Default Bar Code Format:
① Weigh or Fix Price Format
② By Count Format
③ Receipt Format
2 9 C1 C2 C3 C4 C5 C6 P2 P3 P4 P5 C/D
0 2 C2 C3 C4 C5 C6 PC/D P1 P2 P3 P4 C/D
0 2 C2 C3 C4 C5 C6 PC/D P1 P2 P3 P4 C/D
0 0 0 C2 C3 C4 C5 0 0 0 0 C6 C/D
0 2 0 0 0 0 PC/D P1 P2 P3 P4 P5 C/D
Current format
Flag UPC # Price Total check digit
Changed format
Flag UPC #
weight check digit.
Total check digit
Example)
6
PROG.
ESC.
Page 2
<MENU>
the column to be set.)
Format # 1: WEIGH
Format # 2: BY COUNT
Format # 3: FIX PRICE
Format # 4: RECEIPT
ENTER
Set the flag.
ex) Enter “02”.
item. (refer to NOTE 8)
ex) Press the key twice to
select UPC # as a setting
item.
Enter an UPC #.
(Left) (Right)
ENTER
1◇ ◇
Switch over
UPC # →PC/D
Set price
check digit
Switch over
PC/D →UPC #
◇
q
q
2 3 4 5 6
NEXT
PLU
or
1 2 3 4
Comments to this Manuals