TOSLINE-S20 Active Star Coupler (ASC25) Instruction Manual 6F3B0360
TOSLINE S20 27
9.2 Connection of optical fiber cables (cords)
Connection is made between FC Type connectors, or between F07 Type connectors. For
the case of CH1 and CH10, the connectors are FC Type, so that a transmission connector (TX) of
the Active Star Coupler shall be connected to the FC Type receiving connector (OR) on the target
station, and that a receiving connector (RX) of the Active Star Coupler shall be connected to the
FC Type transmission connector (OT) on the target station, using respective optical cables.
For the connection between Active Star Couplers, a transmission connector (TX) of an
Active Star Coupler shall be connected to a receiving connector (RX) of another Active Star
Coupler, further a receiving connector (RX) of an Active Star Coupler shall be connected to a
transmission connector (TX) of another Active Star Coupler, using respective optical cables.
(Notes)
At Active Star Coupler side, arbitrary port among CH1 through CH10 may be selected. (TX
and RX of CH1 and CH10 are in a pair form.)
To the optical transmission/receiving sections (ports) which are not connected with cables
shall be applied with black caps to avoid incoming ambient natural lights. Unnecessary lights
may induce error-functioning.
F07 Type station
Active Star Coupler
FC Type station
Figure 9.4 Method for connecting an Active Star Coupler with stations
Active Star Coupler
Active Star Coupler
Figure 9.5 Method for connecting Active Star Couplers