7.3.3 When Changing Settings of MANUAL mode (Synchro. Scan mode)
Up/down movement
by MENU UP/DOWN
Set by DATA
UP/DOWN
-- 1 SENS -- <FILE A>
<SENS MODE=MANUAL, SHUTTER MODE=SS>
MODE MANUAL
SHUTTER SS
SYNCRO SCAN 30FLD
CMG OFF
GAIN OFF
LEVEL 0
PEAK/AVE AVERAGE
AREA PRESET A
Display of SCENE file
SENS mode AUTO, MANUAL
Electronic shutter mode MANUAL, SS
Synchro. Scan shutter speed
9/262.5H, 10/262.5H, , 255/262.5H,
OFF, 2FLD, 4FLD, 6FLD, , 256FLD
Electronic multiplication gain
OFF, CMG1, CMG2, , CMG10
Circuit gain OFF, 1dB, 2dB, , 18dB
(1) Changing the setting of Synchro. Scan shutter speed
q Using the [MENU UP] or [MENU DOWN] button, place “on SYNCHRO SCAN.
w Using the [DATA UP] or [DATA DOWN] button, select the shutter speed.
[DATA UP]
9/262.5H 255/262.5H OFF 2FLD 256FLD
[DATA DOWN]
Long term
exposure
* Electronic multiplication gain and circuit gain can be set as in the case of MANUAL
electronic shutter mode. (Refer to 7.3.2 (2)/(3))
When setting the MANUAL long term exposure, the automatic iris cannot used.
Note