7.3.2 When Changing Settings of MANUAL mode and MANUAL Shutter mode
Up/down movement
by MENU UP/DOWN
Set by DATA
UP/DOWN
-- 1 SENS -- <FILE A>
<SENS MODE=MANUAL, SHUTTER MODE=MANUAL>
MODE MANUAL
SHUTTER MANUAL
MANUAL 1/100s
CMG CMG7
GAIN OFF
LEVEL 0
PEAK/AVE AVERAGE
AREA PRESET A
Display of SCENE file
SENS mode AUTO, MANUAL
Electronic shutter mode MANUAL, SS
Electronic shutter speed OFF, 1/100s, 1/250s, 1/500s,
1/1000s, 1/2000s
Electronic multiplication gain OFF, CMG1, CMG2, , CMG10
Circuit gain OFF, 1dB, 2dB, , 18dB
(1) Changing electronic shutter speed
q Using the [MENU UP] or [MENU DOWN] button, place “on MANUAL.
w Using the [DATA UP] or [DATA DOWN] button, set the electronic shutter speed.
[DATA UP]
OFF 1/100s 1/250s 1/500s 1/1000s 1/2000s
[DATA DOWN]
(2) Changing the setting of electronic multiplication gain
q Using the [MENU UP] or [MENU DOWN] button, place “on CMG.
w Using [DATA UP] or [DATA DOWN] button, set the electronic multiplication gain.
Increase by [DATA UP]
OFF CMG1 CMG10
Decrease by [DATA DOWN]
(3) Changing the setting of circuit gain
q Using the [MENU UP] or [MENU DOWN] button, place “on GAIN.
w Using [DATA UP] or [DATA DOWN] button, set the circuit gain.
Increase by [DATA UP]
OFF 1dB 18dB
Decrease by [DATA DOWN]