Toshiba RAS-M10SKV-E Datasheet Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
Inverter console
BI-FLOW – TWO OUTLETS FOR
COMPLETE PERSONALISED FLOW
CHILD LOCK FUNCTION ON UNIT
DISPLAY PANEL
FLOOR HEATING MODE
DEODORISING EFFECT
Consoles are an innovative and
compact unit which can be
installed on the oor or in low wall
applications, perfect for under the
window sills or in a low ceiling attic.
With a distinctive oor heating
function, Toshiba inverters can
deliver powerful ow at oor level
for consistent and comfortable
room heating.
heat pump system
C = cooling mode
H = heating mode
Features
Toshiba Multi-Splits are equipped
with Toshiba DC hybrid inverter,
an enhanced feature that ensures
improved performance and
reliability.
Thanks to the ecient DC
compressors, these units provide
fast and precise temperature
management, with high energy
savings compared to xed-speed
systems.
Multi-Split outdoor unit
Key features
For wide range of applications.
A perfect combination of DC twin
rotary compressor, DC Hybrid Inverter
and R-410A refrigerant.
Superior reliability, due to the
reduction of the compressor ON/OFF
cycles.
Compact, silent and light.
Flexible – this system allows up to
25m piping length for one room
as long as the overall length is not
exceeded.
Multi-Split Systems
TOSHIBA AIR CONDITIONING
6
7
Indoor unit RAS-B10UFV-A RAS-B13UFV-A RAS-B18UFV-A
Air ow (h/l) m³/h – l/s C 468 – 130 510 – 142 600 – 167
Sound pressure level (h/l/q) dB(A) C 39/26/23 40/27/24 46/34/31
Sound power level (h/l) dB(A) C 54/41 55/42 61/49
Air ow (h/l) m³/h – l/s H 510 – 142 552 – 153 642 – 178
Sound pressure level (h/l/q) dB(A) H 39/26/23 40/27/24 46/34/31
Sound power level (h/l) dB(A) H 54/41 55/42 61/49
Dimensions (h × w × d) mm 600 × 700 × 220 600× 700 × 220 600 × 700 × 220
Weight kg 16 16 16
Inverter Multi-Split Outdoor units
Outdoor Unit - Reverse Cycle Model RAS-M18UAV-E RAS-3M26UAV-E RAS-4M27UAV-E RAS-5M34UAV-E1
Number of indoor units 2 Rooms 3 Rooms 4 Rooms 5 Rooms
Cooling Capacity - Rated (min - max) KW 5.2 (1.40 ~6.20) 7.5 (4.2~9.0) 8.0 (4.20 ~ 9.20) 10.0 (3.70 ~ 11.00)
Heating Capacity - Rated (min - max) RS 5.6 (0.90~ 8.50) 9.0 (3.0~11.2) 9.0 (3.00 ~ 11.70) 12.0 (3.40 ~ 14.00)
Dimension (H x W x D) mm RS 550 x 780 x 290 890 x 900 x 320 795 x 900 x 320 890 x 900 x 320
Weight Kg RS 40 69 65
EER / COP Rated RS 3.25/3.62 3.75/4.09 3.2/4.2 3.42/4.24
Max Pipe Length m RS 30 70 70 80
Max Pipe Per Unit m RS 20 25 25 25
Chargeless Length m RS 20 40 70 40
Max Height Dierence m RS 10 15 15 15
Sound Pressure (H) at 1 metre dB(A) RS 50 48 48 54
Refrigerant Type R410a R410a R410a R410a
Compressor Type DC Twin Rotary DC Twin Rotary DC Twin Rotary DC Twin Rotary
Operating Range
Celcius
Cooling 5~43 10~43 10~43 10~43
Heating -10 ~24 -15~22 -10 ~22 -10 ~22
Power Supply V/ph/Hz 240-1-50 240-1-50 240-1-50 240-1-50
Note: The capacity per indoor unit will vary in cases where the continuous and simultaneous operation of multiple indoor units are required.
Care should be taken when sizing these applications Please consult your Toshiba Specialist Dealer for more detailed information
COMPACT, LIGHT
OUTDOOR UNIT
UP TO 80 M PIPE RUN
Page view 3
1 2 3 4 5

Comments to this Manuals